Importing From Linkage X3

syn.bike opens a Linkage X3 .ltx file as a bike you can edit and save.

Opening Linkage X3 Files

Open an .ltx file like any other bike file: use the folder icon in the load panel, Open File in the app menu, or Ctrl+O.

The bike loads as a new, unsaved bike. Its Brand, Model Year and Model Name come from the file, and its Version is 0.1.0. Check it, then save it to a database. In the desktop app, Save File asks for a new file name, so the Linkage X3 file is never overwritten.

Supported Linkage Types

The left column is the type name as Linkage X3 stores it, which is how the error message names an unsupported type.

Linkage X3 type Opens as
MonoPivot Single pivot
FourBar, VPPFourBar, Swingarm4Bar Four-bar
4BarShockLinkage, VPPShockLinkage, Sw4BarShockLinkage, SixBarBBL Six-bar
Slider1, MacPhersonShock Slider

Other types are refused with a message such as Linkage type SixBarCH is not supported yet.

What Carries Over

From the Linkage X3 file Notes
Brand, model and year If the file has no model name, the project name is used.
Linkage pivots and shock mounts
Frame geometry Reach and stack (taken from the top of the head tube), head angle, head tube length, fork offset, fork length (axle to crown), lower headset stack, rear center and BB drop. Seat tube angle, seat tube length and crank length come across when the file has them.
Fork travel
Shock stroke A file set to automatic stroke gets the stroke at which the wheel reaches the file's maximum wheel travel.
Drivetrain Chainring, cassette, idler and floating brake. If the file stores a chain length, the bike loads with the chain length locked to it.
Tire diameters

The bike has one size. Images, outlines, rider and spring data are not read, and flip chips are not created.

Linkage X3 File Messages

Message Cause
Linkage X3 file is corrupt: followed by a detail The file could not be read. Save it again from Linkage X3.
This Linkage file uses an older format (version N). Open it in Linkage X3 and save it again, then load the new file. The file was written by an older version of Linkage X3.
Linkage type the type is not supported yet The linkage type is not in the table above.
MacPherson w/ Shock with the strut fixed to the frame is not supported yet Only the other MacPherson arrangement can be opened.
The file's max wheel travel of N mm must be a positive number An automatic-stroke file with no usable wheel travel. Set the travel in Linkage X3 and save again.
Could not reach the file's max wheel travel of N mm — the linkage stops at M mm The linkage cannot move as far as the travel the file asks for.

Other messages name the point or setting that is missing or unreadable in the file.