# DAQ Settings and Device

> Reference for the DAQ Config tab in syn.bike, with every processing setting, its unit and default, and what the Device tab shows from a connected synDAQ logger.

This page is the reference for every DAQ (data acquisition) processing setting in syn.bike, and for what the **Device** tab shows. The **Config** tab on the [DAQ page](https://syn.bike/docs/data-acquisition/overview.md) holds the processing settings. The **Device** tab shows live readings from a logger connected over Bluetooth.

Settings are saved to your account and apply to whichever recording you load, so check them when you switch to a recording from a different bike.

![The Config tab with the Travel and leverage and Advanced processing settings sections open, showing the default values](https://syn.bike/images/docs/daq-config-light.png)

## Travel and Leverage

The **Travel & leverage** section of the **Config** tab turns the sensor readings into fork, rear wheel and shock travel, so the leverage source, the two sensor strokes, and the fork and shock travel have to match the bike. See [Set Travel and Leverage](https://syn.bike/docs/data-acquisition/overview.md#set-travel-and-leverage).

## Advanced Processing Settings

Click **Advanced processing settings** to open the section. Most recordings need none of them changed.

| Setting | Default | What it does |
| --- | --- | --- |
| **Sample rate (Hz)** | `2000` | The logging rate, used only when the file carries no timing of its own. |
| **ADC bits** | `12` | The resolution of the travel sensor readings from the logger's ADC (analog-to-digital converter), from `8` to `16` bits. |
| **Filter cutoff (Hz)** | `100` | The cut-off of the low-pass filter applied to travel. It must be below half the recording's sample rate. |
| **Stroke threshold (mm/s)** | `70` | The speed below which the suspension counts as not moving. |
| **Min stroke (mm)** | `2` | Strokes shorter than this are discarded. |
| **Stroke idle time (ms)** | `20` | How long the speed can stay under the threshold before the current stroke is ended. |
| **Bottom-out threshold (%)** | `95` | Travel above this share of the total counts as a bottom-out. |
| **Speed zone split (mm/s)** | `250` | The shaft speed that separates low-speed from high-speed compression and rebound in velocity histograms and summaries. |
| **Brake threshold (counts)** | `3500` | A brake sensor reading below this counts as applied. A released brake reads about `4000` counts and drops close to `0` when the lever is pulled. |
| **Front brake** | `Brake 1` | Which of the logger's two brake inputs the front brake is wired to. **Rear brake** is always the other one. |
| **Invert ADC** | On | Leave on when a higher sensor count means less travel. Turn off if travel plots come out upside down. |
| **Zero point** | **Lowest travel** | Not a setting. Each travel sensor is zeroed at the most extended position it reached in the recording. |

After changing **Sample rate (Hz)** or **ADC bits**, load the file again. Everything else takes effect straight away.

A value the field cannot accept is flagged with "Enter a valid value" and is not saved.

### Travel Filtering

Only the travel channels are filtered, and filtering does not shift them in time. Velocity is the slope of the filtered travel.

Lowering **Filter cutoff (Hz)** gives cleaner velocity traces and histograms but rounds off sharp impacts and lowers peak speeds. Raising it does the reverse. Compare peak speeds only between recordings processed with the same cut-off.

### Stroke Detection

Strokes feed the **Strokes** count, the balance plots and the compression and rebound statistics.

Raise **Stroke threshold (mm/s)** or **Min stroke (mm)** to ignore small trail chatter and keep only the larger hits. Lower them if a smooth track leaves the balance plots nearly empty.

## Device Tab

The **Device** tab is a live readout from a synDAQ logger, for checking that every sensor reads sensibly before a run. It does not start or stop logging, download recordings or change settings on the logger. Recordings still come off the SD card.

### Browser Support

Connecting needs Chrome or Edge on desktop, or Chrome on Android. Firefox, Safari and the [syn.bike desktop app](https://syn.bike/docs/desktop-app.md) cannot connect. Loading recordings with the file field works in every browser.

Two browsers need a flag turned on first:

| Browser | Flag |
| --- | --- |
| Chrome on Linux | Open `chrome://flags/#enable-experimental-web-platform-features`, set it to Enabled and relaunch Chrome. The Linux Bluetooth service (BlueZ) must be running and the adapter switched on. |
| Brave | Enable `brave://flags/#brave-web-bluetooth-api`. |

### Connect a Logger

1. Switch the logger on and stay within Bluetooth range.
2. Click **Connect** on the **Device** tab.
3. Pick the logger in the browser's pairing window. Its name starts with `synDAQ`.

The state changes from **Not connected** through **Connecting…** to **Connected**. If the link drops, the page shows **Reconnecting** and tries again by itself. **Disconnect** ends the session.

### What the Device Tab Shows

| Section | Contents |
| --- | --- |
| **Device** | The battery level (hover for the voltage), the connection state, and the GPS fix with the number of satellites. The info icon opens **Device details** with the name, model, manufacturer and versions. The versions are those of the Bluetooth module, not the logger firmware. |
| **Live travel** | Bars for **Front** and **Shock** in mm and as a percentage of **Fork travel (mm)** and **Shock travel (mm)** from the **Config** tab. Travel is measured from the end of each sensor's stroke, not from a zero found in a recording. |
| **Acceleration** | The current reading in g for **Front**, **Rear**, **Frame** and **Handlebar**. A sensor that never reports is not fitted. |
| **Device log** | Recent messages from the logger, in a section you can expand. |

Live data pauses while either chip is shown: **File Transfer Mode** (the SD card is mounted over USB) or **Logging** (the logger is recording to the SD card).

### Connection Problems

| Message | What to do |
| --- | --- |
| "Lost the connection to the synDAQ. Check it is powered on and in range, then reconnect." | Check the logger and click **Reconnect**. |
| "Web Bluetooth is not available. Use Chrome or Edge on desktop or Android." | Switch browser. See [Browser Support](#browser-support). |
| "No telemetry for a few seconds." | The logger is connected but has stopped sending travel data. Check whether it is logging or in file transfer mode. |